HOME > Overview of interface buildup work

Overview of interface buildup work

  1. We implemented interface using such standard technologies that enable to acquire simply and easily necessary information (image, report, etc.) on electronic medical record. (Order Placer) (by Fujitsu Ltd.)
  2. Between radiology information system and modalities, not only patient information but also examination content must be registered directly to modalities. This registration is based on JJ1017 version 3.0 code that respects interoperability and is conducted according to connection guidelines that use DICOM standard. For this purpose, we implemented new connection. (Order Filler, etc.) (by Yokogawa Electric Corporation)
  3. About image delivery to electronic medical record, we studied the connection to identify the delivered image, and image delivery technology. We added implementation of appropriate interface.
    (Image Manager・DICOM/HL7-G/W)
    (by Konica Minolta Medical & Graphic, Inc.)
  4. If image information was given off line from the systems of other hospitals, then it must be simply and easily incorporated with connection. For this purpose, we implemented the import function based on PDI integration profile. (Media Importer) (by Konica Minolta Medical & Graphic, Inc.)
  5. About report creation system, IHE-J Clinical Planning Committee Report Workflow WG studied conformance of the report workflow in Japan, based on the report workflow integration profile. This WG and JIRA Reading Report Study Committee formed Joint Study Committee, which is Reading Report Study Committee. We respected its study result and conducted restructuring that contributed to interoperability.
    (Report Reader・Report Creator・Report Manager・Report Repository)
    (by Hitachi Medical Corporation)
  6. About delivery of report to electronic medical record, we studied the connection to identify delivery documents and the delivery technology. Then, we added implementation of a suitable interface.
    (Report Manager・Report Repository) (by Hitachi Medical Corporation)
  7. At Acquisition Modality, as information connection specification from the information system, we used JJ1017 version 3.0 code recommended by IHE-J guidelines, and built up intelligible interface for the first time in Japan. (X-ray DR system: Acquisition Modality)
    (by Toshiba Medical Systems Corporation)
  8. We assumed image presentation from other hospitals. We built up the system that can create CD-R containing images based on PDI integration profile. We built it on the Image Display terminal that can operate independently.
    (Media Creator) (by ImageONE Co., Ltd.)

    » System connection situation in verification experiment
    » Content of implementation of fiscal 2005 verification research